While installing OIM 12c (12.2.1.3.0), I didn't use the standard port 14000 and didn't provide any value for OIM Front End URL. I didn't face any issue during installation and saw the success message at the end.
The moment I hit the Import or Export menu items, I saw a 'BLANK SCREEN'. In the logs, I was surprised to see that it was trying to connect to 14000.
In enterprise manager, I was able to see 14000 as the port for Front End URLs. I changed 14000 to the correct OIM port that helped in loading the Import and Export forms properly.